QC Electrical Engineer
?? +966-545723559 ?? [email protected] ?? Riyadh, Saudi Arabia
Transferable Iqama Date of Birth: 27th September 1989 Marital Status: Married.
Objective
Electrical Engineer with over 10 years of progressive experience, specializing in power distribution systems,
building electrification, and utility-scale infrastructure projects. Proven expertise in managing underground
external electrification, RMUs, transformer installations, solar PV systems, and high-rise/residential electrical
works from design through execution. Strong command over quality assurance/quality control (QA/QC)
procedures, inspection protocols, and compliance with international electrical standards (IEC, NEC, IEEE).
Demonstrated ability to lead multidisciplinary teams, ensure regulatory compliance, manage documentation,
and maintain high standards in safety, system reliability, and project delivery. Committed to delivering high-
quality results through strong leadership, technical expertise, and a proactive approach to problem-solving.
CORE COMPETENCIES
• MV/LV Underground Electrification.
• Distribution Transformers, RMU’S, Cable Laying Termination & Jointing.
• 132kV AIS Grid Substation (Initial Design review & Documentation).
• Electrical Works – Residential Villas & High-Rise Buildings.
• Testing & Commissioning of MV/LV system.
• Solar PV System Installation & Grid Integration.
• Quality Control, ITPs, Material Inspections & Site Quality Inspections.
• Technical Documentation & Reporting.
• Street Lighting Systems – Pole Erection, Control Panels, LED Fixtures.
• BOQs, Technical Submittals, Cable Schedules, Load Schedules.
• Team Management, Site Supervision & Contractor Coordination.
EMPLOYMENT CHRONICLE
M
QA/QC Engineer – Electrical Feb 2025 – Present
PROJECT DETAILS:
Project Name & Client : Roshn – Sedra Phase 04 Project, Riyadh, KSA.
Main Contractor : China Harbour Engineering Company Ltd (CHEC) Riyadh, kSA.
Consultant : East Consultant Engineering Center (ECEC).
KEY RESULT AREAS:
? Preparing work/ material inspections requests (WIR/MIR) for consultant (ECEC) approval.
? Coordination with site engineers of all trades and ensures the timely completion of related activities before
the Clearance / Installations inspection.
? Ensuring all works are carried out in compliance with Approved drawings, Project specifications and QCS.
? Perform daily internal inspections / Consultant inspections and testing of the scope and character necessary to
achieve the quality of construction required in the drawings, specifications for all works under the contract.
? Conduct a walk down inspection and generate Snag list (Punch List.)
? Report inspections and test results to the QA/QC / Project manager.
? Report any electrical finding to Operation Foreman and Field Supervisor, issue INCR.
? Coordinate with the consultant’s representative and Site In-charge for inspections and NCR dispute points.
? Witnessing tests and verifying reports against regulations, approved method of statement procedures, for all LV/
ELV installations.
? Ensure that as Built Drawings, O&M Manuals and related documentations are prepared, reviewed, submitted and
approved in a timely manner in accordance with contract requirements.
? Follow up and updating the cleared snags and getting approval from the client, for final handing over.
? Taking care of QA/QC documents of the entire project including certificates, calibration, test results, inspection
requests, Non-compliance Closeout reports and site instruction/observations.
Deputy Manager – Electrical Dec 2018 – Jan-2025
PROJECT DETAILS:
Project Name & Client : New Lahore City ( Ph- 1, 2, 3, 4 ), Zaitoon City, Zaitoon Lifestyle Lahore, Pakistan.
Main contractor/Client : Zaitoon Group, Lahore, Pakistan.
Consultants : MEP Solutions (Pvt) Ltd, Powercom consultanats, LESCO, Pakistan.
KEY RESULT AREAS:
? Execution and supervision of underground power distribution network including MV/LV cable laying, jointing, and
termination works.
? Installation & commissioning of 11kV/400V distribution transformers, RMUs, LV panels, and Feeder Pillars.
? Design coordination and implementation of street lighting system with galvanized steel poles, LED luminaires, and
astronomical time switches.
? Preparing inspection & test reports of completed inspections & tests.
? Ensuring all equipment’s, tools and materials meet with the project quality requirements and that personnel have
been adequately trained to use them safely.
? Perform Material receiving inspections as Per ITP and Project Specification.
? Verifying that all necessary inspections and tests, as required of the project and statutory regulations, are carried
out and appropriate records are updated and maintained.
? Attend FAT/SAT activities to witness the inspection and testing’s for Electrical equipment’s.
? Co-ordination with Building Automation system of LV panels, fire Alarm system, Automation of HVAC system,
lighting system automation based on luminous intensity of natural Instrument Responsibilities:.
? Installation cabling, megger test termination, loop checking, functional test and Commissioning work.
? Installation Inspection for different types of conduits, cable trays for Power and control cables.
? Installation Inspection and testing for earthing, lightning system rods, overall loop Grounding resistance.
? Conduct & Witness Inspection activities i.e. Installation of Oil filled transformers, testing and commissioning
activities of Transformer’s up to Voltage level 34.5KV, 11KV, 415V.
? Witness Inspection activities i.e Vaccuming, SF6 Gas filling and Gas testing activities of Switchgears like RMU’S.
? Witness of MV cable screen separation kit & Splicing Joint Conducted by Approved cable Vendor.
? Involve in Installation Inspection of medium voltage & low voltage cable laying of 11 KV & 0.415 KV volts Cable.
? Witness of medium voltage testing such as megger & very low frequency AC high Pot-test for cables.
? Involve in Installation, testing inspection related to Oil filled Distribution transformer for 11kv, 4.15kv such as
Insulation resistance, winding resistance, transformer turns ratio, Power factor test, Impedance voltage, MV side no
load current test, LV side no current test, Bushing Current test, dielectric strength test for oil, Stability test .
? Installation, testing related for equipment rated up to 11 KV/0.415 KV Switchgear and 415V Motor Control Centre
such as Insulation resistance of Bus bar and