BASHARAT ASLAM
Electrical and instrumentation Engineer
[email protected] +966 59 721 3485 AL Khobar , Saudi Arabia Age : 27
Iqama No : 2630263891 Iqama Validity : 09-04-2027 (Transferable) Nationality: Pakistani


PROFILE SUMMARY


Electrical Engineer with hands-on experience in large-scale industrial environments, specializing in the installation, maintenance, calibration, and troubleshooting of complex electrical and instrumentation systems. Proven trackrecord in designing, commissioning, and optimizing electrical and control systems, including sensors, transmitters, actuators, and high-load machinery, to ensure safe, reliable, and efficient plant operations. Skilled in implementing control systems, monitoring power quality, and performing preventive, predictive, and corrective maintenance.


EDUCATION


Bsc Electrical Engineering UET , Taxila , Pakistan 2018 - 2022
FSC Pre Engineering Alpine Degree College of Sciences, Pakistan 2016 - 2018


WORK EXPERIENCE


Bonyan Construction Company Site Engineer Jan 2025 - Present


Responsibilities:

Supervise and coordinate site activities to ensure work is executed in accordance with approved
drawings, specifications, quality standards, and project schedules.
Coordinate with clients, consultants, subcontractors, and suppliers to ensure smooth project execution and timely issue resolution
Manage material planning, procurement, storage, inventory control, and site logistics.
Prepare BOQs, quantity take-offs, inspection requests (IRs), and project documentation.
Conduct quality inspections and ensure compliance with project specifications, QA/QC procedures, and consultant requirements.
Monitor project progress, enforce safety standards, and support timely project delivery within budget
Executed installation, testing, commissioning, and troubleshooting of electrical and control systems,
including low-voltage switchgear, panels, motors, VFDs, and power distribution networks for production
lines.
Performed preventive, predictive, and corrective maintenance to ensure continuous operations and
minimize downtime.
Installed and routed cables through EMT conduits, cable trays, and cable trunks, performed cable
pulling, ensuring organized routing, mechanical protection, and compliance with safety standards.
Prepared and executed electrical layouts for production lines, including LV distribution boards, VFD
panels, and motor connections.
Contributed to engineering studies and technical analyses, providing recommendations for effective
project execution.
Assisted in the preparation of detailed electrical designs, drawings, technical specifications, calculations,
and engineering reports.
Operated and monitored SCADA systems, performing data analysis, system checks, and performance
verification.
Maintained critical power systems, including UPS and backup support systems, to ensure the
uninterrupted operation of essential equipment.
Designed and installed fire alarm systems, including detectors, panels, and signaling circuits, integrated
with plant safety systems.
Implemented earthing and grounding for all panels, motors, VFDs, cable trays, and fire alarm circuits to
maintain electrical safety and system reliability.
Monitored and managed power optimization, efficiency, and load balancing to improve energy usage and
system performance.
Maintained documentation including electrical layouts, cable schedules, conduit paths, wiring diagrams,
fire alarm circuits, UPS connections, and as-built drawings.


Gadoon Textile Mills Limited (UNIT 1,3,9) Electrical Engineer (E&I) feb 2023 - Jan 2025


Responsibilities:

Responsible for maintenance and troubleshooting of industrial electrical machinery from major OEM
manufacturers including Rieter, Murata, Toyota, Trützschler, Howa, and Crossrol.
Responsible for preventive, predictive, and corrective maintenance of electrical and automation
systems, ensuring maximum reliability and minimal downtime.
Performed pre-commissioning and functional testing of LV switchgear, transformers, panels, and
motors—including insulation resistance (Megger), continuity, protection relay verification, CT Testing,
VFD and soft starter testing, interlock testing, cause-and-effect testing, motor solo run, and load
testing—in accordance with IEC standards and project specifications.
Installed and conducted loop checks and calibrated pressure, level, temperature, distance, IR and flow
transmitters using a HART communicator and calibrators.
Worked with various industrial sensors, including proximity sensors, photoelectric sensors, encoders,
RTDs, differential pressure transmitters, load cells, and yarn clearer sensors.
Programmed and tuned PID controllers and modified Siemens PLCs using TIA Portal for AC plant
automation and control systems, improving process reliability and operational efficiency.
Operated and analyzed CONAIR SCADA-based automation systems for HVAC/AC plants, performing system monitoring, QC checks, data trending, and functional verification to ensure stable
environmental control and reliable process operation.
Designed control systems and implemented operating techniques for BOGE compressors and the pump system to ensure efficient performance.
Ensured reliability of UPS-backed critical systems by conducting periodic inspections, load testing,
battery bank maintenance, and fault diagnostics to minimize downtime.
Prepared detailed electrical layouts and schematics for three production units using AutoCAD, ensuring compliance with operational requirements.
Worked extensively with LV electrical systems, including panels, motor feeders, protection devices.
തിരികെ അടുത്തത്