❖ Intermediate Chemical Company (Member of Al Swadi group)
• I regularly check and clean the equipment, oil moving parts, ensure
proper alignment, and monitor for any unusual sounds or vibrations to
catch issues early.
• Inspecting the electrical panels and connections testing continuity and
voltage level replace worm and damage components.
• Testing the pneumatic system and pneumatic cylinders pneumatic valve
pneumatic fittings and limit switch.
• Configuration and update HMI & PLC setting troubleshooting display and
input issues.
• To manage a Variable Frequency Drive (VFD), adjust load settings,
frequency, and motor parameters in the control panel. For
troubleshooting, check fault codes and resolve issues as per the VFD
manual, while also ensuring connections and grounding are properly
verified.
• Perform the routine checking on generator and ATS panel. and schedule
maintenance of the generators.
❖ Electrical workshop 1-year Saudi Arabia.
• Electrical wiring installation, cable pulling switches board breakers (MCB
RCCB MCCB)
• Installation and underground wiring pipe & ducting as par design.
❖ Himont Group (June 2022 - March 2023).
• Repair all electrical control panels (MB, DB, switch gear) equipment and
machines
• Checking back up power source (UPC, generator, Solar) and its
maintenance and chack it’s working properly.
• Installation new industrial machines as per design and chack it’s working
properly.
• Installation and maintenance IP CCTV cameras and it’s configuration with
DVR & NVR.
• Maintenance of AC units and insulation and fault detection (gas pressure,
Capacitor, compressor overheating power supply)
• Motor stater panel (DOL, Star Delta, VFD) insulation and connection and
maintenance of the panel and motor
• Control Room records and monitor the temperature & load LT panels
working.
❖ Shakarganj Suger Mill LTD (Jhang) (January 2021 - May 2022).
• Collected load and maintained machines, motors, and control boards.
• Assisted in troubleshooting & repairing electrical control panels.
• Understanding and implementing design form technical diagrams.
• Inspecting and testing electrical components cables during and after
product installation (MCB, RCB, MCCB, RCCB, Magnetic contractor,
relays, timer, CT & PT, push button, HMI,)
• Identify and report electrical problems for example short circuit open
circuit over load and motor temperature control circuit problem etc.
• Inspect electrical panels HT & LT and its equipment and earthing
insulator bus bars.
• Create records for material used.